Temporary Static Line Systems - Metal Roofs

$1,865.00 $1,492.00
You save $373.00
INC GST

Buy 4 or more and receive a further 10% discount


FREE SHIPPING


Current Stock:
SKU:
AMSLTEMPRA
Availability:
This product usually ships within 3-4 business day's.
Weight:
10.00 KGS
  • Visa
  • Mastercard
  • Paypal
  • Apple Pay

Temporary Static Line Systems Fully Compliant to AS/NZS - Metal Roofs

(360 Degree Use)  australian-made-rs.jpg

"20% OFF RRP - Limited Time"

Permanent fix roof anchor static line systems also available, CONTACT US

 

Need fully compliant roof anchors to AS/NZS ?  WE HAVE YOU COVERED

  • The ONLY "fully compliant" roof anchor TESTED & APPROVED by a division of SafeWork NSW ( NATA accredited for testing roof anchor points to AS/NZS 1891.4:2009 - current standard of compliance ) tested to 15kn of static load ( approximately 1.5 tonnes of load in direction of fall ) refer to our test report. Certificate of Test Report

  • Who can install roof anchor points and roof anchor static line systems - anchor points can be installed and used by a competent person, as per AS/NZS 1891.4:2009 and AS/NZS 1891.2:2001 Supplement 1:2001 part 2, products installed and used as per manufactures user manual click here for installation user manual 

  • Simple installation method, with QR code manufactures installation, selection, use, maintenance manual and colour coded installation instructions on each roof anchor ( for easy install )

  • Not competent ? that's ok - CONTACT US and we will have one of our preferred installers install your static lines for you, Australia wide service

  • Comes with, fastenings

  • Fully compliant to AS/NZS 1891.4:2009 and AS/NZS 1891.2: Supplement 1:2001 Part 2

  • Default colour Hi Vis Orange

  • Default length ( approximately 7.5 meters ) with adjusters suited for different roof sheet pattens and profiles

  • Adapts to the x3 most common types of metal roof sheeting;

          1. Custom Orb / Corrugated

          2. Spandeck

          3. Trimdeck / Monoclad / Steelclad

          -  Klip-Lok 700 ( not available in temporary application, available as permanent fix ONLY )

 

We guarantee your safety with our products 

IMPORTANT NOTE:

  Roof anchors and static line systems MUST comply with the AS/NZS 1891.4:2009 and AS/NZS 1891.2 supplement 1:2001 as referenced in the falls code of practice

 

 

HOW TO INSTALL - TEMPORARY ROOF ANCHOR STATIC LINE SYSTEM - Metal Roof

Place ANKAme Temporary anchor points into position as per (owner’s manual installation instructions) and in desired location, follow manufactures user manual for correct installation, selection, use and maintenance as per AS/NZS

 

HOW TO INSTALL - PERMANENT ROOF ANCHOR STATIC LINE SYSTEM - Metal Roof
Place ANKAme Permanent anchor point into position as per (owner’s manual installation instructions) and in desired location, follow manufactures user manual for correct installation, selection, use and maintenance as per AS/NZS

 

ROOF ANCHOR, SELECTION, USE, MAINTENANCE & INSPECTION

It is a requirement that the roof anchor be inspected prior to each use, if any of the following are evident, the roof anchor must be removed from service immediately: Any defects, absent markings/ labelling, evidence of missing parts, or if the roof anchor has been used in a fall. Roof anchor not to be used in a corrosive environment. Permanent anchor to be used in the direction of eyebolt only. Roof anchor to be used only where roof sheeting has been fully installed in accordance with manufacturers recommendations. Roof sheeting profile can vary up to 5mm, inspect roof sheeting prior to installation of roof anchor. Roof anchor to be cleaned regularly with a damp cloth. Re-Inspection of Permanent roof anchor systems are to be every 12 months as per AS/NZS

REFER TO USER MANUAL FOR CORRECT INSTALLATION AND USE CLICK HERE

 

AS/NZS compliance

Complies with:
AS/NZS 1891.4: 2009
Single Point Anchorage (15Kn)

Complies with:
AS/NZS 1891.2: Supplement 1:2001 Part 2
Static Line Use (15Kn)

RATED TO 15kN ( ONE PERSON PER SYSTEM, AS PER AS/NZS )

 

DISCLAIMER

By purchasing a ANKAme anchor point static line system you are deemed to be a competent installer, or have contacted a competent installer, as the manufacturer and seller take no responsibility for the misuse of the products. Refer to owners manual installation instructions for the correct use of these items. If in doubt contact an engineer. 

 

FAQ / Read more ....

 

When do I need to use a temporary or permanent roof anchor static line system ?

  • The Work at Height Regulations 2005 state that whenever there is the potential for a person to fall while working and this leads to injury, then the worker must have some form of protection. What type of protection depends on a risk assessment being carried out and a method of protection selected from the hierarchy of control

Why are roof anchor static lines required and used ?

  • A roof anchor static line is used as a safety device to protect a worker from falling at heights

What is a temporary roof anchor static line system ?

  • A temporary roof anchor static line system is a devise fastened to the top of a metal roof where a worker will then attach there harness rope to the 7.5 meter long static line system to secure themselves with a safety harness 

Who can use a temporary or permanent roof anchor static line system ?

  • As per the Australian standards a competent person can install and use a roof anchor point and static line system, as per the manufactures installation user manual and AS/NZS

Who can install a temporary or permanent roof anchor static line system ?

  • As per the Australian standards a competent person can install and use a roof anchor point, as per the manufactures installation and user manual

How do you install a temporary roof anchor static line system?

  • As per the Australian standards a competent person can install and use a roof anchor point, as per the manufactures installation instructions and user manual

How to test a roof anchor point ?

  • A roof anchor point can be tested as per AS/NZS 1891.4:2009 ( table 3.1 ), load tested to 15Kn of load, that's approximately 1.5 tonners of load, in the direction of a potential fall 

What is the minimum strength of a roof anchor point ?

  • The minimum strength for a roof anchor point for 1 person is 15Kn ( 1 person per roof anchor per system ) as per As/NZS 1891.4:2009

How do you use a temporary or permanent roof anchor static line system ?

  • You need to deem yourself competent and refer to the manufactures installation instructions user manual, if in doubt you need to consult and engineer or contact the manufacture

How often do roof anchors need to be inspected ? 

  • As per the AS/NZS all roof anchors need to be visually inspected prior to each use, and for permanent roof anchors a annual inspection is required every 12 months from the date of installation

When and how to inspect a roof anchor ?

  • Every day you turn up to a roof where roof anchor points are already installed or needs to be installed you must check they are fully compliant to AS/NZS 18914:2009, you must also refer to the owners manual for correct installation and use, if in doubt ask the manufacture or contact a structural engineer 

How many roof anchor static line systems do you need on a roof ?

  • It is the responsibility of a competent person to understand how many roof anchor static line systems are required as each roof type and layout is different to the next, or you would need to contact US to locate a competent installer in your area. if in doubt contact a structural engineer 

How far apart should roof anchor static line systems be ?

  • It is the responsibility of a competent person to understand how many roof anchor static line systems are required as each roof type and layout is different to the next, or you would need to contact US to locate a competent installer in your area

 

Contact a roof anchor installer near me ?

  • contact us if you need assistance with installations of our ANKAme roof anchor static line systems and height safety equipment

Can the ANKAme permanent roof anchor static lines be installed on corrugated roofs and other common metal roof types ?

  • Yes the ANKAme roof anchor static line system adapts to corrugated roofs, spandeck roofs, trimdeck roofs, klip-lok roofs

 

Height Safety Shop ALL

 

 

 

Product Reviews


★ ★ ★ ★ ★
We install ANKAme height safety products across Melbourne, we wouldn’t use any other product, roof anchors come with signed test report for customer satisfaction and compliance to current AS/NZS 1891.4:2009.

- Joe Conway

Roof anchor and height safety installations servicing all areas of Melbourne
0412728773

★ ★ ★ ★ ★
I have tradesmen come to do work on my two story house. And I do not want anyone to slip from working from two stories especially cleaning gutters etc. Therefore I value this addition feature to our house to keep our tradesmen safe

- Ian Davey

Home owner, Melbourne

★ ★ ★ ★ ★
We recently purchased 6 roofer kits from ANKAme height safety and are very happy with the quality and usability of the products, the roof anchors are very easy to install as they come with QR user guide and colour coded installation instructions on each anchor. Perfect for what we need. Totally recommend this product for anyone wanting compliant height safety products to keep their staff safe when working at heights.

- Derek Phillips

Charged Energy Servicing all areas of Queensland
0483880771

★ ★ ★ ★ ★
Purchased a permanent roof anchor directly from ANKAme. Product arrived quickly and exactly as described. Installation was straight forward and John at ANAKme responded quickly to questions by email.

- Mark Bonnar