Permanent Roof Anchor Point | Metal Roofs

OUT OF STOCK DUE TO HIGH DEMAND, NEW STOCK ARRIVING SOON

FREE SHIPPING


Current Stock:
SKU:
PERMRA
Availability:
This product usually ships within 3-4 business day's.
Weight:
3.00 KGS
  • Visa
  • Mastercard
  • Paypal
  • Apple Pay

 

PERMANENT ROOF ANCHOR POINT - Metal Roofs | Australian Made 

 

Need fully compliant Australian made height safety permanent roof anchor points to AS/NZS. WE HAVE YOU COVERED .... (2023)

Temporary roof anchor click here

 

  • The ONLY fully compliant permanent roof anchor point TESTED & APPROVED by TEST SAFE AUSTRALIA ( NATA accredited for testing roof anchor points to AS/NZS 1891.4:2009 ) tested rated to 15kn of static load ( approximately 1,500 kilograms of load in direction of fall ) refer to our test report. Certificate of Test Report as per the SafeWork Australia falls code of practice

  • Who can install roof anchor points - permanent roof anchor points can be installed and used by any competent person, tradie or DIY, as per AS/NZS 1891.4:2009 and as per manufactures user manual

  • Not competent ? that's ok - CONTACT US and we will have one of our preferred roof anchor installers install your permanent roof anchor points for you, Australia wide service 

  • Simple installation method, with QR code user manual and colour coded installation instructions on each permanent roof anchor point ( for easy install ) UV protected stickers

  • Comes with, pop rivet fastenings, installation tag ( need riveting tool for installation of rivets CLICK HERE )

  • Strong and durable ( 3kg )

  • Made from HI-GRADE STEEL, sandblasted, primer painted in a rust proof primer paint, then finished with a durable powder coated finish 

     

  • Default colour Gull Grey     

  • Approximate size 45mm X 45mm X 955mm

  • Aligns to the 5 most common metal roof sheet profiles and concrete fix

         -  Custom Orb / Corrugated
         -  Spandeck
         -  Trimdeck / Monoclad / Steelclad
         -  Klip-Lok 700
         -  Klip-Lok 500
         -  Concrete fix

We guarantee your safety with our products

IMPORTANT NOTE:

Roof anchors MUST comply with AS/NZS 1891.4:2009 roof anchor testing and compliance (15kN of "load") 

 AS REFERENCED IN THE FALLS CODE OF PRACTICE AND AS ALSO NOTED IN THE SAFEWORK NSW FACT SHEET

 

HOW TO INSTALL PERMANENT ROOF ANCHOR POINTS - Metal Roof
Place ANKAme permanent anchor point into position as per (owner’s manual installation instructions) fasten to roof with specified fastenings

 

HOW TO INSTALL PERMANENT ROOF ANCHOR POINTS - Concrete
Place permanent anchor point into position as per (owner’s manual installation instructions) fasten to min. grade 32mPa concrete with specified fastenings

 

PERMANENT ANCHOR POINTS

(min. grade sheet thickness 0.42mm) fixed to surface of roof sheeting ribs with Bulb-tite 7.7mm x 27mm RV6605-9-6W rivets, fixed in sequence as indicated below
To be installed and used by competent persons

 

HEIGHT SAFETY PERMANENT ROOF ANCHOR, USER INSPECTION & MAINTENANCE

It is a requirement that the roof anchor be inspected prior to each use, if any of the following are evident, the roof anchor must be removed from service immediately: Any defects, absent markings/ labelling, evidence of missing parts, or if the roof anchor has been used in a fall. Roof anchor not to be used in a corrosive environment. Permanent anchor to be used in the direction of eyebolt only. Roof anchor to be used only where roof sheeting has been fully installed in accordance with manufacturers recommendations. Roof sheeting profile can vary up to 5mm, inspect roof sheeting prior to installation of roof anchor. Roof anchor to be cleaned regularly with a damp cloth

 

Complies with:
AS/NZS 1891.4: 2009
Single Point Anchorage (15Kn)

 

Complies with:
AS/NZS 1891.2: Supplement 1:2001
Static Line Use (15Kn)

 

Related Products

The permanent fix roof anchor rivets require special tooling, that we can also provide. They are the Hand Rivet Gun or the Battery Rivet Gun

 

DISCLAIMER

By purchasing a PERMANENT ANKAme roof anchor point you are deemed to be a competent installer, or have contacted a competent installer, as the manufacturer and seller take no responsibility for the misuse of the products. Refer to owners manual installation instructions for the correct use of these items. If in doubt ask.

 

**NEW product design ANKAme Permanent roof anchor static line system CLICK HERE to find out more ....

 

FAQ / Read more ....

 

When do I need to use a permanent roof anchor point

The Work at Height Regulations 2005 state that whenever there is the potential for a person to fall while working and this leads to injury, then the worker must have some form of protection. What type of protection depends on a site-specific risk assessment being carried out and a method of protection selected from the hierarchy of control.

Why are roof anchors required and used 

A roof anchor is used as a safety device to protect a worker from falling at heights and can be installed and used by a competent person, as per manufactures user manuals and AS/NZS.

What is a permanent roof anchor point 

A permanent roof anchor point system is a height safety devise fastened to the top of a metal or tile roof where a worker will then attach there harness rope line to secure themselves with a safety harness.

Who can use a permanent roof anchor point systems 

As per the Australian standards and the SafeWork Australia falls code, a competent person can install and use a roof anchor point, as per the manufactures installation and user manual.

Who can install a permanent roof anchor points 

As per the Australian standards and the SafeWork Australia falls code, a competent person can install and use a roof anchor point, as per the manufactures installation and user manual.

What is a competent person 

A competent person is a person who has, through a combination of training, education and experience, acquired knowledge and skills enabling that person to correctly perform a specified task.

How do you install height safety permanent roof anchor points 

Permanent roof anchor points must be installed as per the Australian standards. A competent person can install and use roof anchor points, as per the manufacture's installation and user manual.

How to test a roof anchor points 

A roof anchor point can be tested as per AS/NZS 1891.4:2009 ( table 3.1 ), load tested to 15Kn of load, that's approximately 1.5 tonners of load, in the direction of a potential fall. No further onsite testing is required.

What is the minimum strength of a roof anchor point 

The minimum strength for a roof anchor point for 1 person is 15Kn ( 1 person per roof anchor per system ).

How do you use a temporary or permanent roof anchor point 

You need to deem yourself competent and refer to the manufacture's installation instructions user manual.

How often do roof anchors need to be inspected  

As per the AS/NZS all roof anchors need to be visually inspected prior to each use, and for permanent roof anchors an annual inspection is required every 12 months from the date of installation.

When and how to inspect a roof anchor points 

Every day you turn up to a roof where roof anchor points are already installed or needs to be installed you must check they are fully compliant to AS/NZS 18914:2009, you must also refer to the owner's manual for correct installation and use, if in doubt ask the manufacture or contact a structural engineer. 

How many roof anchor points do you need on a roof 

It is the responsibility of a competent person to understand how many roof anchor points on a roof are required as each roof type and layout is different to the next, or you would need to contact the manufacture to locate a competent installer in your area.

How far apart should roof height safety anchor points be installed 

It is the responsibility of a competent person to understand how many roof anchor points are required as each roof type and layout is different to the next, or you would need to contact the manufacture to locate a competent installer in your area.

Contact us if you need competent height safety roof anchor point installer

Contact the roof anchor point manufacture if you need assistance with installations of ANKAme roof anchor points and height safety equipment.

Can the ANKAme permanent roof anchor points be installed on corrugated roofs and other common metal roof types 

Yes the ANKAme roof anchor adapts to corrugated roofs, spandeck roofs, trimdeck roofs, klip-lok roofs and concrete fix.

Permanent roof anchors near me 

Yes, the ANKAme permanent roof anchors and height safety equipment are sold online and with over 33 trusted resellers Australia wide all states. 

      What is a roof anchor point 

A roof anchor point is a roof safety device that's attached to a metal or tile roof area, installed, used and maintained by a competent person as per manufactures installation, selection use and Maintenace manual and AS/NZS 1891.4:2009.

       What is a compliant roof anchor point 

A compliant roof anchor point is a roof safety devise that complies with AS/NZS 1891.4:2009 as referenced in the Safe Work Falls Code Of Practice. The roof anchor must meet 15kN of "load" that's (approximately 1,500kg of load). The roof anchor point must also come with installation user manual, products correctly labelled with manufactures brand, batch numbering, selection and use details, specified fastenings labelled, sold with specified fastenings, fastenings must meet minimum breaking strengths, products cannot be installed in a corrosive environment - ie. non compatible materials or corrosive roof environments.

 

 

Height Safety Shop ALL

 

 

We recently purchased 6 roofer kits from ANKAme height safety and are very happy with the quality and usability of the products, the roof anchors are very easy to install as they come with QR user guide and colour coded installation instructions on each anchor. Perfect for what we need.

Totally recommend this product for anyone wanting compliant height safety products to keep their staff safe when working at heights.

- Derek Phillips

We install ANKAme height safety products across Melbourne, we wouldn’t use any other product, roof anchors come with signed test report for customer satisfaction and compliance to current AS/NZS 1891.4:2009. Roof anchor and height safety installations servicing all areas of Melbourne 0412728773

- Joe Conway

I recently purchased temporary roof anchoring equipment and found the product very easy to use, made of quality materials - essential for working safely on roofs. The equipment arrived in satisfactory time with no hassles. I would definitely use ANKAme again for roof safety equipment.

- Rob Baker

I bought an Ankame temporary anchor point more than a year ago. My business is building repairs & maintenance so we are often on domestic roofs. It is easy to use and was delivered promptly. I highly recommend this product.

- David Kay